Diseño de una nueva prueba para medir la función de sensibilidad al contraste con iPad

2015

[EN] Purpose: To introduce a new application (ClinicCSF) to measure Contrast Sensitivity Function (CSF) with tablet devices, and to compare it against the Functional Acuity Contrast Test (FACT). Methods: A total of 42 subjects were arranged in two groups of 21 individuals. Different versions of the ClinicCSF (.v1 and .v2) were used to measure the CSF of each group with the same iPad and the results were compared with those measured with the FACT. The agreements between ClinicCSF and FACT for spatial frequencies of 3, 6, 12 and 18 cycles per degree (cpd) were represented by Bland---Altman plots. Results: Statistically significant differences in CSF of both groups were found due to the change…

AdultMalemedia_common.quotation_subjectVision DisordersVisual performanceFACTDesempeño visualCycles per degreeContrast SensitivityYoung Adultlcsh:OphthalmologyStatisticsHumansContrast (vision)lcsh:QC350-467Tablet devicesDiagnosis Computer-AssistedSensitivity (control systems)Simulationmedia_commonContrast sensitivity functionDispositivos de tabletaVision TestsMiddle AgedFunctional acuity contrast testConfidence intervalTest (assessment)Función de sensibilidad al contrasteiPadlcsh:RE1-994Computers HandheldFISICA APLICADAOriginal ArticleFemaleSpatial frequencyPsychologyEFAClcsh:Optics. LightOptometry
researchProduct

Multichannel functional testing in normal subjects, glaucoma suspects, and glaucoma patients

2012

Purpose.: To evaluate visual function with a novel multichannel functional test named the ATD Multichannel Functional Test. Methods.: This multicenter study had a prospective and cross-sectional design. A total of 186 eyes were included: 42 with glaucoma, 14 glaucoma suspects due to optic nerve characteristics, 25 ocular hypertensives, and 105 normal eyes. All patients performed standard visual fields (Humphrey 24-2) and ATD with eight stimuli configurations: four achromatic (A), two red-green (T), and two blue-yellow (D). To derive main outcome measures, mean sensitivity, mean defect (MD), and pattern standard deviation (PSD) were calculated and compared among groups and types of stimuli w…

AdultMalemedicine.medical_specialty61genetic structuresFunctional testingGlaucomaAudiologyCycles per degreeContrast SensitivityPattern standard deviationOjos--EnfermedadesReference ValuesOphthalmologyOptic Nerve Diseases617MedicineHumansProspective StudiesIntraocular PressureAgedbusiness.industryVision TestsReproducibility of ResultsGlaucomaMiddle Agedmedicine.diseaseNormal limiteye diseasesOphthalmologymedicine.anatomical_structureCross-Sectional StudiesMulticenter studyOftalmologiaEye--DiseasesOptic nerveOftalmologíaFemaleOcular Hypertensionsense organsVisual FieldsbusinessUlls--MalaltiesColor PerceptionOptic disc
researchProduct

Visual quality differences between orthokeratology and LASIK to compensate low-moderate myopia.

2013

PURPOSE: To assess the differences in visual performance between orthokeratology (ortho-k) and laser in situ keratomileusis (LASIK) for the treatment of low-to-moderate myopia. METHODS: An adaptive optics visual simulator (Imagine Eyes) was used to simulate the wavefront aberration patterns induced by ortho-k and LASIK for low and moderate myopia on 10 healthy eyes. Visual acuity (VA) at 100%, 50%, and 10% contrast levels and contrast sensitivity (CS) at 10, 20 and 25 cycles per degree (cpd) were then measured for 3- and 6-mm pupil sizes. RESULTS: Differences in VA for 3-mm pupil diameter were not found between ortho-k and LASIK. For 6-mm pupil size, LASIK provided significantly better VA v…

AdultMalemedicine.medical_specialtyVisual acuitymedicine.medical_treatmentmedia_common.quotation_subjectKeratomileusis Laser In SituVisual AcuityKeratomileusisPupilCycles per degreeContrast SensitivityYoung AdultOphthalmologyMyopiaMedicineContrast (vision)Humansmedia_commonAnalysis of Variancebusiness.industryOrthokeratologyPupil sizeLASIKOphthalmologyFemalemedicine.symptombusinessOrthokeratologic ProceduresCornea
researchProduct

Contrast sensitivity after implantation of toric iris-claw lenses in phakic eyes.

2004

Abstract Purpose: To evaluate the change in contrast sensitivity after implantation of the Verisyse toric phakic intraocular lens (IOL) (AMO) for the correction of myopia with astigmatism. Setting: Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods: Eighteen eyes had implantation of an iris-supported toric phakic IOL to correct myopia with astigmatism. The mean preoperative spherical equivalent was −12.65 diopters ± 3.6 (SD). The contrast sensitivity with best spectacle correction was determined before surgery and 3 months after surgery using the CSV-1000 HGT instrument (Vector Vision Inc.). Results: Three months after IOL implantation, the mean contrast sen…

Adultmedicine.medical_specialtygenetic structuresmedia_common.quotation_subjectAstigmatismPhakic intraocular lensProsthesis DesignCycles per degreelaw.inventionContrast SensitivityLens Implantation IntraocularlawOphthalmologyLens CrystallinemedicineMyopiaContrast (vision)HumansPhakic iolIris clawDioptremedia_commonLenses Intraocularbusiness.industryAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologySurgerysense organsbusinessJournal of cataract and refractive surgery
researchProduct

In vitro optical performance of nonrotational symmetric and refractive-diffractive aspheric multifocal intraocular lenses: impact of tilt and decentr…

2012

Purpose To evaluate the optical quality of Acrysof Restor SN6AD1 refractive–diffractive +3.00 D and Lentis Mplus LS-312 nonrotational symmetric +3.00 D aspheric multifocal intraocular lenses (IOLs) and analyze the effect of tilt and decentration. Setting University of Valencia, Valencia, and University of Murcia, Murcia, Spain. Design Experimental study. Methods An artificial model eye was used to measure wavefront aberrations of both IOL models. The modulation transfer function (MTF) and point-spread function (PSF) were calculated for a 5.0 mm pupil and under 5 situations: centered, 0.2 mm and 0.4 mm decentered, and 2 degrees and 4 degrees tilted. Results The refractive–diffractive IOL had…

WavefrontPhysicsLenses IntraocularOptics and Photonicsbusiness.industryAberrometryMultifocal intraocular lensModels TheoreticalArtificial Lens Implant MigrationProsthesis DesignRefraction OcularRefractionSensory SystemsCycles per degreeOphthalmologyOpticsTilt (optics)Optical transfer functionAberrometryOptometryHumansSurgerySpatial frequencybusinessJournal of cataract and refractive surgery
researchProduct

Impact of the pupil size – central optical zone diameter relationship on visual performance in aspheric multifocal contact lenses

2020

Abstract Purpose To determine the impact of different central optical zone diameters (COZDs), obtained from pupil size, on the visual performance of presbyopic subjects fitted with centre-distance simultaneous-image multifocal contact lenses (SIMCLs). Methods Thirty-two presbyopic volunteers, between 45–58 years of age, participated in this prospective, controlled, double-blind study. Subjects were fitted with 5 centre-distance SIMCLs of variable COZD, determined from the measurement of pupil size under photopic light conditions and corresponding to 60, 70, 80, 90 and 100 % of pupil diameter. Subjects visual performance was evaluated through the measurement of distance, intermediate and nea…

medicine.medical_specialtyVisual acuitygenetic structuresContact Lensesmedia_common.quotation_subjectVisual AcuityPupil diameterNear visual acuityCycles per degreeContrast SensitivityDouble-Blind MethodOphthalmologymedicineHumansContrast (vision)Prospective Studiesmedia_commonMathematicsPupil sizePupilGeneral MedicineMiddle Agedeye diseasesOphthalmologySpatial frequencymedicine.symptomOptometryPhotopic visionContact Lens and Anterior Eye
researchProduct